1.5–7.5 kW · 2.2–11 kWp array · no battery, tank as storage

A solar water pump price is quoted per cubic metre delivered, not per kilowatt of panel. The three numbers that set it are total head (static lift plus drawdown plus pipe friction), the daily volume the crop or the community needs, and the hours of usable sun in the worst month. A 1.5 kW pump lifting 40 m delivers 8–10 m³/h at midday; the same pump at 90 m delivers 4 m³/h, and no amount of extra panel changes the hydraulics.

Typical pump size

1.5–7.5 kW

Array per kW pump

1.4–1.6 kWp

Daily volume

20–250 m³

This page is the sizing method we use for boreholes, rivers and irrigation schemes in Nigeria, Ghana and South Africa. It covers the load table, three standard pump-and-array combinations, indicative EXW price bands, why most pumping systems should not have a battery, the voltage and certification differences between markets, and the installation details — dry-run protection, cable sizing, tilt — that decide whether the borehole still fills the tank in year four.

Why diesel pumping costs more than the sticker

A 3 kW diesel pump set burns about 1.1 litres an hour, so six hours of irrigation is 6.6 litres a day. Over a 200-day season that is 1,320 litres; at USD 1.10–1.40 a litre delivered to a farm, USD 1,450–1,850 a season, every season, before the oil changes, the impeller rebuilds and the trips to town for fuel.

The failure mode is not the fuel price, it is the logistics. When the pump is 40 km from the nearest filling station, a missed delivery costs a day of irrigation, and a day of irrigation at flowering can cost more than the whole season's fuel. Solar removes that dependency, which is why the payback calculation is usually about yield protection rather than kWh price.

The other mistake is putting a battery on a pumping system. Water is the cheapest battery there is: pump into an elevated tank during the day and let gravity deliver at night. A battery adds 40–60% to capital cost, loses 10–15% round-trip, and is the first component to fail in a hot pump house.

  • ✓1,300+ litres of diesel a season at USD 1.10–1.40/litre delivered
  • ✓Fuel runs that fail during flowering, when a lost day costs the crop
  • ✓Battery banks added to pumping systems that do not need them
  • ✓Pumps sized on rated power instead of head and flow at the actual duty point
  • ✓No dry-run protection, so the pump destroys itself the first time the water table drops

Typical pump load values

Pumping load is hydraulic, not electrical: power follows flow × head. The table uses 55–65% wire-to-water efficiency for a DC submersible and 5.0 peak-sun hours for the array calculation.

ItemPowerHoursDaily energy
0.75 kW surface pump, 15 m head0.75 kW5 h3.8 kWh
1.5 kW submersible, 40 m head1.5 kW6 h9.0 kWh
3 kW submersible, 60 m head3.0 kW6 h18.0 kWh
5.5 kW submersible, 80 m head5.5 kW6 h33.0 kWh
7.5 kW surface set, flood irrigation7.5 kW6 h45.0 kWh

Array size = pump kW × 1.4–1.6 for a DC pump with an MPPT VFD, or × 1.8 for an AC pump on a solar VFD. The multiplier covers the pump's part-load behaviour at 10:00 and 15:00, when irradiance is 60–70% of peak but the crop still needs water.

Recommended configurations

These three combinations cover a smallholder plot, a commercial horticulture block and a village water supply. All are direct-drive: no battery, storage in a tank sized for one night of demand.

TierPV arrayBatteryPower electronicsServes
P1 — 1 ha vegetable plot2.2 kWp (10 × 230 W)None — 10 m³ elevated tank1.5 kW DC pump + 2.2 kW MPPT VFD9 kWh/day, 40 m head, 45–55 m³/day
P2 — 5 ha drip block4.6 kWp (20 × 230 W)None — 30 m³ tank3 kW DC pump + 4 kW MPPT VFD18 kWh/day, 60 m head, 80–100 m³/day
P3 — village supply / 20 ha11 kWp (48 × 230 W)Optional 10.24 kWh for night demand7.5 kW pump + 11 kW VFD45 kWh/day, 80 m head, 200–250 m³/day

Size the tank before you size the array. One night of village demand at 15 m³ means a 15 m³ tank, which costs far less than the battery that would replace it. For drip irrigation, the tank also lets you run the pump at full power into storage instead of throttling to match the emitters.

Indicative cost ranges (USD, EXW Ningbo)

Bands below are for the complete pumping kit: pump, MPPT VFD or controller, modules, mounting frame, level probes and 30 m of submersible cable. Drilling, casing, tank, pipework and installation are excluded.

ItemSpecificationIndicative range
P1 kit — 1.5 kW2.2 kWp PV · DC submersible · MPPT VFDUSD 1,450 – 1,950
P2 kit — 3 kW4.6 kWp PV · DC submersible · MPPT VFDUSD 2,650 – 3,400
P3 kit — 7.5 kW11 kWp PV · pump · 11 kW VFDUSD 6,200 – 7,900
Galvanised array frameGround mount, adjustable 10–35°, 120 km/hUSD 120 – 480
Level probe + dry-run relayStainless electrodes, IP68USD 45 – 90
  • Indicative EXW ranges for hardware only; final price depends on head, flow, pump brand tier and port. A borehole log usually changes the pump selection.
  • Solar kits above replace a 3 kW diesel set that spends USD 1,450–1,850 a season on fuel — payback is typically two to three seasons.
  • Borehole drilling and casing are quoted locally and often exceed the solar hardware cost; budget USD 3,000–8,000 for a 60–100 m borehole in West Africa.

All prices on this page are indicative EXW ranges compiled from current container quotations. They are not a binding offer: freight, duties, installation and exchange rates move, and the final price is issued after we receive your load list and delivery port.

Local adaptation: voltage, climate and certification

Pumping systems are installed by local contractors, so the array and controller have to match the local supply and the local water conditions. These are the four markets we quote most.

MarketGrid & codeClimateCertification
Nigeria230 V / 50 Hz; most pumps run standalone, NEMSA for public water schemes40 °C ambient, sandy water, harmattan dust on the arraySONCAP for imported pumps, IEC 62253 for PV pumping
Ghana230 V / 50 Hz; Energy Commission approval for imported equipmentHigh humidity, iron-rich groundwater in the coastal beltEC registration, IEC 62253
South Africa230 V / 50 Hz; SANS 10142-1 for any grid-connected pump house−5 °C winter mornings, boreholes 80–150 m deepSANS 10142-1, SABS for pressure equipment
Philippines220 V / 60 Hz — 60 Hz motors, and 220 V not 230 VTyphoon wind loads, 2,000 mm rain, volcanic sedimentDOE compliance, NTC not applicable to pumps

Installation points that protect the pump

1

Set the pump depth above the drawdown

Install the pump at least 3 m below the lowest recorded water level, and fit a level probe. A pump that runs dry destroys its thrust bearing in under a minute.

2

Size cable for voltage drop, not ampacity

Keep total DC drop under 3%: at 120 m and 10 A, that means 6 mm² copper, not the 2.5 mm² that comes with the kit. Undersized cable is the most common reason a correctly sized pump underperforms.

3

Tilt the array for the dry season

Use latitude minus 5° to favour the dry months when irrigation demand peaks: 25–30° in South Africa, 10–15° in Nigeria and Ghana. A steeper tilt also sheds dust.

4

Use the tank as the battery

Size storage for one day of peak demand and let the pump run at full power into it. Throttling a pump to match drip emitters wastes 20–30% of the harvestable energy.

5

Fit a VFD with MPPT, not a fixed-voltage controller

An MPPT VFD keeps the array at its maximum power point as irradiance falls, which extends the pumping day by 1.5–2 hours at both ends. Fixed-voltage controllers lose most of the morning and evening.

6

Protect the borehole head

Concrete plinth, lockable cap, and a cable gland that keeps rainwater out. In sandy aquifers, a missing cap fills the screen within two seasons.

Frequently asked questions

How much does a solar water pump system cost?

A 1.5 kW borehole kit with 2.2 kWp of PV and an MPPT VFD is USD 1,450–1,950 EXW. A 3 kW kit is USD 2,650–3,400 and a 7.5 kW village-scale kit USD 6,200–7,900. Drilling, casing, tank and installation are local costs and often exceed the solar hardware: budget USD 3,000–8,000 for a 60–100 m borehole in West Africa.

Do I need a battery for a solar water pump?

No, in almost every case. Water is cheaper to store than electricity: pump into an elevated or ground tank during the day and use gravity or a small booster at night. A battery adds 40–60% to capital cost, loses 10–15% round-trip and is the first thing to fail in a hot pump house. The exception is night-only demand, such as poultry water lines or a night irrigation shift.

How many panels do I need for a 3 kW solar pump?

About 4.2–4.8 kWp, or 19–21 × 230 W modules. The rule is pump kW × 1.4–1.6 for a DC pump with an MPPT VFD, because the array must still deliver at 10:00 and 15:00 when irradiance is 60–70% of peak. For an AC pump on a solar VFD the multiplier rises to about 1.8.

How much water can a solar pump deliver per day?

At 60 m total head, a 3 kW pump moves roughly 20 m³/h at midday and about 110 m³ over a six-hour pumping window with a 4.6 kWp array. At 40 m head the same pump delivers 30–35 m³/h. Always calculate from the pump curve at the actual head, not from the datasheet maximum flow.

What happens on cloudy days?

Output falls roughly with irradiance, so a heavily overcast day may deliver 30–40% of the clear-sky volume. Two design responses: size the tank for two days of demand, or oversize the array by 20% and accept a longer pumping day. Adding a battery is the expensive third option and rarely justified for irrigation.

Send the borehole log

Give us static water level, drawdown, casing diameter, required daily volume and the crop or community served. We will return a pump curve, array layout and EXW price within two working days.