Split-phaseIP20
Split-phase inverter 8–12 kW
DLXN-OCT-P-II-8/10/12KW
Native 120/240 V split-phase output for North America — no external transformer. UL 1741 and FCC listed platform.
- Rated output
- 8 / 10 / 12 kW
- Phases
- 120/240 V split-phase · 3-phase parallel
- Max PV input
- 16 / 20 / 24 kW
- MPPT
- 65–500 Vdc · 27 A × 2
- Battery
- 48 Vdc · 190–250 A charge
Full specifications
| AC Output(Off Grid) | |
|---|---|
| Rated Power | 8kW/8kVA 10kW/10kVA 12kW/12kVA |
| Surge Power | 16kW/16kVA 20kW/20kVA 24kW/24kVA |
| AC Output Voltage | Single Phase: 100V/110V/120V/127V ,Split Phase: 120V/240V 2/3 Phase: 127V/220V ,Parallel Mode Three-Phase: 120V/208V |
| Rated AC Output Frequency | 50Hz / 60Hz (Auto detection) |
| Max Inverter Efficiency | 96.5% (PV/AC) |
| Transfer Time | <10ms@Single, <20ms @ Parallel |
| Output Waveform | Pure Sine Wave |
| No-Load Loss | ≤75W@Rate Voltage |
| AC Output(On Grid) | |
| Power Factor | 0.8 leading to 0.8 lagging |
| Rated Voltage | Single Phase: 100V/110V/120V/127V ,Split Phase: 120V/240V ,2/3 Phase: 127V/220V ,Parallel Mode Three-Phase: 120V/208V |
| Rated Grid Frequency | 50Hz/60Hz (Auto detection) |
| Max Output Current | 34A(Split Phase) 67A(Single Phase) 42A(Split Phase) 84A(Single Phase) 50A(Split Phase) 100A(Single Phase) |
| PV Input | |
| Number Of MPPT Trackers | 2 |
| Max PV Input power | 8000W*2 10000W*2 12000W*2 |
| Max PV Array Open Circuit Voltage | 550Vdc |
| Max PV Input Current | 27A*2 |
| Startup Voltage | 75Vdc |
| MPPT Voltage Range | 65~500Vdc |
| MPP tracking efficiency | 99.9% |
| Battery | |
| Compatible Battery Types | Lead-acid,Lithium battery |
| Rated Battery Voltage | 48V/51.2V |
| Battery Voltage Range | 38.4Vdc~60Vdc |
| Cold Start Battery Voltage | 46Vdc |
| Max Solar Charging Current | 190A 210A 210A |
| Max AC Charging Current | 190A 210A 250A |
| Max Charging Current (PV+AC) | 190A 210A 250A |
| Activate The Lithium Battery Function | PV/AC |
| Protection | |
| Over Current/Voltage Protection; Anti-islanding Protection; AC Short-Circuit Protection; Leakage Current Protection; Grid Monitoring; Ground Fault Monitoring; DC Surge Protection OVC II; AC Surge Protection OVC III | |
| Mechanical Specifications | |
| Inverter Dimensions | 541*518.7*141.2mm |
| Packing Measurements | 626.5*603*5*231mm |
| Net Weight | 21.2kg 21.3kg 21.5kg |
| Gross Weight | 24.4kg 24.5kg 24.7kg |
| Environment | |
| Protection Degree | IP20 |
| Humidity | 5%~95% non-condensing |
| Altitude | <2000 Meters |
| Operating Temperature | -10℃~50℃ |
| Storage Temperature | -15℃~60℃ |
| Noise | <75dB |
| Certificate | UL 1741,FCC |