Hybrid, off-grid and three-phase inverters, 6–22 kW
One 48 V battery platform across the range. Every unit does grid-tied, off-grid and backup in the same box, with dual MPPTs, dual AC outputs, built-in ATS and a generator port — parallel up to 9 units for 198 kW.

Off-grid inverter 6 kW
DLXN-BIN-S-I-6KW
Dual AC outputs with a dedicated smart-load port, built-in ATS for generator transfer, up to 9 units in parallel. Built for sites with no grid at all.
- Rated output
- 6 kW / 6 kVA
- Phases
- Single-phase 230 V
- Max PV input
- 8 kW (2 × 4 kW MPPT)
- MPPT
- 65–450 Vdc · 16 A
- Battery
- 48 Vdc · 100 A charge

Hybrid inverter 6 kW
DLXN-OCT-S-I-6KW
Grid-tied and off-grid in one box: self-consumption by day, battery backup at night. Dual AC outputs keep critical loads on their own circuit.
- Rated output
- 6 kW / 6 kVA
- Phases
- Single-phase 230 V
- Max PV input
- 9 kW (2 × 4.5 kW MPPT)
- MPPT
- 65–450 Vdc · 18.5 A
- Battery
- 48 Vdc · 100 A charge

Hybrid inverter 8–12 kW
DLXN-OCT-S-I-8/10/12KW
The workhorse for large homes and small business: central AC, commercial kitchen loads, 2 MPPTs for split roof orientations.
- Rated output
- 8 / 10 / 12 kW
- Phases
- Single-phase 230 V
- Max PV input
- 12 / 15 / 18 kW
- MPPT
- 65–450 Vdc · 27 A × 2
- Battery
- 48 Vdc · 190–250 A charge

Hybrid inverter 8–12 kW, IP54
DLXN-OCT-S-I-8/10/12KW-IP54
Same platform in a IP54 enclosure for verandas, garages and semi-outdoor walls.
- Rated output
- 8 / 10 / 12 kW
- Phases
- Single-phase 230 V
- Max PV input
- 12 / 15 / 18 kW
- MPPT
- 65–450 Vdc · 27 A × 2
- Battery
- 48 Vdc · 190–250 A charge

All-in-one inverter + 16 kWh
DLXN-ESS-S-I-1606
Inverter and 16 kWh LiFePO4 in one enclosure — less rack, less cable, less installation labour. Parallel up to 9 units for small mini-grids.
- Rated output
- 6 kW / 6 kVA
- Phases
- Single-phase 230 V
- Max PV input
- 9 kW (2 × 4.5 kW MPPT)
- MPPT
- 65–450 Vdc · 18.5 A
- Battery
- 51.2 V · 314 Ah (16 kWh)

Split-phase inverter 8–12 kW
DLXN-OCT-P-II-8/10/12KW
Native 120/240 V split-phase output for North America — no external transformer. UL 1741 and FCC listed platform.
- Rated output
- 8 / 10 / 12 kW
- Phases
- 120/240 V split-phase · 3-phase parallel
- Max PV input
- 16 / 20 / 24 kW
- MPPT
- 65–500 Vdc · 27 A × 2
- Battery
- 48 Vdc · 190–250 A charge

Three-phase inverter 16–22 kW
DLXN-OCT-T-I-16/18/20/22KW
1000 Vdc strings for long runs and low losses; pumps, cold rooms and machine tools straight off the three-phase output. 198 kW at nine units.
- Rated output
- 16 / 18 / 20 / 22 kW
- Phases
- Three-phase 380/400 V
- Max PV input
- 32 / 36 / 40 / 44 kW
- MPPT
- 150–900 Vdc · 40 A × 2
- Battery
- 48/51.2 Vdc · up to 460 A charge
Specifications taken from the supplied datasheets. Battery side accepts 48 V LiFePO4 packs (40–60 Vdc operating range). Parallel units must be the same model and firmware with equal-length AC cables.