Data report · 26 November 2026
Solar + Storage Payback Index 2026
Payback for an identical 5 kWp / 10 kWh system in ten emerging markets — same hardware, same assumptions, local irradiance and local tariffs. The spread is a tariff story, not an equipment story.
The finding
Nairobi and Cairo receive essentially the same sun. The same system pays back four to five times faster in Kenya, because the tariff differs by a factor of 4.5.
- Best market
- 4.5–6.1 yr
- Kenya, business tariff
- Slowest
- 20.4–27.8 yr
- Egypt, business tariff
- Battery share of hardware
- 53–55 %
- 10.24 kWh of the bill
- Markets covered
- 10
- Africa, South & Southeast Asia

Five findings
- 1
Tariffs decide the ranking, not sunshine
Kenya and Egypt sit within 2 % on irradiance and within 3 % on annual yield, yet payback differs by a factor of 4.5. Market-entry analysis that opens with an irradiance map is measuring the wrong variable.
- 2
Residential and commercial economics invert between markets
South African households pay roughly twice the business tariff, so residential payback (3.8–5.2 years landed) beats commercial (7.5–10.3). Pakistan is the mirror image: commercial 5.3–7.3 years against 12.8–17.5 residential.
- 3
The official tariff is the wrong benchmark off-grid
Nigeria reports 62 % electricity access. The other 38 % are not buying power at 0.050 USD/kWh — they run generators or buy nothing. Priced on the official tariff Nigeria is the worst market here; priced against self-generation it is among the best.
- 4
Storage is now the majority of hardware cost
The 10.24 kWh battery is 53–55 % of the hardware bill at current EXW bands. Two years ago this configuration failed the payback test in every market in this table. This index is a snapshot of a fast-moving cost curve.
- 5
Bangladesh is the quiet market
100 % grid access, a 0.102 USD/kWh business tariff and usable irradiance put it at 9.9–13.5 years landed — ahead of Vietnam and Indonesia, and almost never covered in English-language solar media.
The index, market by market
| Market | Sun kWh/m²/day | Yield kWh/yr | Tariff USD/kWh | Payback, EXW | Payback, landed + installed | Residential, landed | LCOE USD/kWh | Grid access |
|---|---|---|---|---|---|---|---|---|
| KenyaNairobi | 5.82 | 8,384 | 0.175 | 2.2–3.0 | 4.5–6.1 | 3.6–4.9 | 0.023–0.032 | 77% |
| PakistanKarachi | 5.61 | 8,085 | 0.152 | 2.7–3.6 | 5.3–7.3 | 12.8–17.5 | 0.024–0.033 | 96% |
| PhilippinesManila | 5.10 | 7,350 | 0.158 | 2.8–3.8 | 5.6–7.7 | 4.2–5.8 | 0.027–0.036 | 95% |
| GhanaAccra | 4.90 | 7,063 | 0.140 | 3.3–4.5 | 6.6–9.0 | 6.1–8.4 | 0.028–0.038 | 92% |
| South AfricaJohannesburg | 5.58 | 8,041 | 0.108 | 3.8–5.1 | 7.5–10.3 | 3.8–5.2 | 0.024–0.033 | 90% |
| BangladeshDhaka | 4.50 | 6,487 | 0.102 | 4.9–6.7 | 9.9–13.5 | 16.0–21.8 | 0.030–0.041 | 100% |
| VietnamHo Chi Minh City | 5.20 | 7,484 | 0.078 | 5.6–7.6 | 11.2–15.3 | 11.2–15.3 | 0.026–0.035 | 100% |
| IndonesiaJakarta | 4.83 | 6,961 | 0.069 | 6.8–9.3 | 13.6–18.6 | 10.4–14.2 | 0.028–0.038 | 100% |
| NigeriaLagos | 4.59 | 6,614 | 0.050 | 9.9–13.5 | 19.8–27.0 | 27.5–37.5 | 0.029–0.040 | 62% |
| EgyptCairo | 5.71 | 8,230 | 0.039 | 10.2–13.9 | 20.4–27.8 | 34.5–47.1 | 0.024–0.032 | 100% |
EXW is the factory-gate band of the equipment. Landed + installed applies a 2× multiplier for freight, duty, installation and commissioning — no scale discount, no financing benefit, no credit for diesel displaced.

Method and sources
Every input is either fetched from a public API or taken from a published DLXN price band, and each one is annotated with the date it was retrieved.
| Input | Value used | Source |
|---|---|---|
| Global horizontal irradiation | Annual climatology per city | NASA POWER climatology API (ALLSKY_SFC_SW_DWN), retrieved 26 Nov 2026 |
| Retail electricity prices | Residential and business, USD/kWh | GlobalPetrolPrices.com country tables, retrieved 26 Nov 2026 |
| Grid access | % of population, 2024 | World Bank EG.ELC.ACCS.ZS |
| Hardware cost | 22 × 230 W modules ($39–53) + 10.24 kWh LiFePO4 ($973–1,331), × 1.25 for inverter, racking, cabling | DLXN Energy published EXW bands, 26 Nov 2026 |
| Landed + installed multiplier | 2.0 × hardware | Assumption, presented as a sensitivity rather than a claim |
| Performance ratio | 0.78 | Assumption (industry range 0.75–0.82) |
| Self-consumption | 70 % of annual yield | Assumption |
| Degradation | 0.5 %/year over 25 years | Assumption |
What this index does not include
- Import duty and VAT, which run 0–35 % depending on market and HS classification.
- Local installation labour, permitting and grid-connection fees.
- Financing cost, O&M, and inverter replacement in year 10–12.
- Any value assigned to backup power, diesel displaced, or carbon avoided — all of which improve the case for storage.
Take the numbers with you
The workbook contains every input, the formula for each column and the retrieval date for each source, on a separate method sheet. If a number disagrees with your own data we would like to know — a model you can argue with is the point of publishing it.
Citation
DLXN Energy (2026). Solar + Storage Payback Index 2026. https://dlxnsolar.com/research/solar-storage-payback-index-2026
Data licensed CC BY 4.0. Charts may be reproduced with attribution to DLXN Energy.
